MODEL |
8205 |
8210 |
INSULATION RESISTANCE |
|
Range |
Resolution |
Accuracy |
Output Voltage, DCV |
30-1000 |
1 |
±(1% of setting+1V) |
Ouput Regulation DCV |
±(1% of output +1V) from no load to full load |
Output Ripple |
<2% |
Discharge |
Automatic Discharge of Device Under Test |
Indicator: Green<30V, Red>30V |
SETTINGS |
Low-Limit Resistance, MΩ |
0.1~999.9 |
0.1 |
Same as Resistance Measurement |
1000~9999 |
1 |
10.0GΩ~50.0GΩ for Model 8205
10.0GΩ~200.0GΩ for Model 8210 |
0.1GΩ |
Delay Time, second |
1~999.9 |
0.1 |
±(0.1% of setting + 0.05sec) |
Dwell Time, second |
0, 0.1~999.0 (0=continuous) |
MEASUREMENT |
|
Range |
Resolution |
Accuracy |
DC Voltage, V |
0.01~100.0
101-1000 |
0.1
1 |
±(1% of setting+1V) |
Resistance |
0.001MΩ~50.0GΩ for Model 8205
0.001MΩ~200.0GΩ for Model 8210
,Auto Range |
0.001MΩ
0.01MΩ
0.1MΩ
1MΩ
0.01GΩ
0.1GΩ |
500–1000V
0.1MΩ - 1GΩ,± (2% of reading + 2 counts)
1GΩ - 20GΩ , ± (3% of reading + 2 counts)
20GΩ –50GΩ,±(10% of reading + 2 counts)
20GΩ–200GΩ,±(10% of reading + 2counts)
30–499V
0.1MΩ-1GΩ,± (3% of reading + 2 counts)
1GΩ - 20GΩ , ± (5% of reading + 2 counts) |
GENERAL |
Input Voltage AC |
115/230Vac±15%, 50/60Hz ± 5%, Fuse 1A/ Fast acting 250VAC |
PLC Remote Control |
Inputs : Test , Reset, Interlock |
Outputs : Pass, Fail , Progressing |
Display |
4 Digits LED Display |
Terminations |
High Voltage Output – Alden Socket |
Shielded Return – BNC Connector |
Safety |
Built-in Smart GFI circuit,GFI trip current 450μA max, HV shut down speed: <1mS |
Calibration |
Built-in software and external calibrated meters |
Environment |
0-40℃, 20-80%RH |
Dimension/Net Wight |
280mm(W)×89mm(H)×300mm(D)/ 4.5Kg |
STANDARD ACCESSORIES |
Power Cord(10A) |
×1 |
Fuses |
×2 (Including a spare contained in the fuse holder) |
Interlock Disable Key(1505) |
×1 |
Hipot Test Lead ,1.5m(1101) |
×1 |
BNC Connector Return Test Lead ,1.15m(1140) |
×1 |
*product specifications are subject to change without notice. |