MODEL |
ESC-112 |
Voltage |
115/230VAC±15%, User selection |
Frequency |
50/60Hz±5% |
Fuse |
2A / 250V Slow-Blow fuse |
Line condition |
Power Switch |
Reverse polarity switch setting select ON / OFF |
Neutral Switch |
Neutral switch on/off selection for single fault condition |
Ground Switch |
Ground switch on/off selection for class I cingle fault condition |
Probe Setting |
Ground to Line (G-L) |
V |
Surface to Line (PH-L) |
V |
Surface to Surface (PH-PL) |
V |
Ground to Neutral (G-N) |
- |
Auto Function(G-L & G-N) |
- |
SETTINGS |
Leakage HI/LO
Trip |
Range |
0uA, 1uA~10000uA (0=OFF) |
Resolution |
1uA |
Leakage HI/LO
Trip(Peak) |
Range |
0uA, 1uA~15000uA (0=OFF) |
Resolution |
1uA |
Leakage Current RMS Display |
Range |
MD Major Resistance is 0.5kΩ |
MD Major Resistance is 1kΩ |
MD Major Resistance is 1.5kΩ |
Range 1 |
0.0uA - 260.0uA |
0.0uA - 130.0uA |
0.0uA - 85.0uA |
Range 2 |
240.0uA - 999.9uA
1000uA - 1050uA |
120.0uA - 525.0uA |
80.0uA - 350.0uA |
Range 3 |
800.0uA - 999.9uA
1000uA - 4200uA |
400.0uA - 999.9uA
1000uA - 2100uA |
266.6uA - 999.9uA
1000uA - 1400uA |
Range 4 |
3600uA - 10000uA |
1800uA - 10000uA |
1200uA - 10000uA |
Leakage Current RMS Display |
Range |
Frequency |
Basic Accuracy |
Range 1-4 |
DC, 15Hz ~ 10kHz |
±(2% of reading + 5 counts) |
10kHz ~ 1MHz |
±(5% of reading) |
Leakage Current Peak Display |
Range |
MD Major Resistance is 0.5kΩ |
MD Major Resistance is 1kΩ |
MD Major Resistance is 1.5kΩ |
Range 1 |
0uA - 260.0uA |
0uA - 130uA |
0uA - 85uA |
Range 2 |
240uA - 1050uA |
120uA - 525uA |
80uA - 350uA |
Range 3 |
800uA - 4200uA |
400.uA - 2100uA |
266A - 1400uA |
Range 4 |
3600uA - 15000uA |
1800uA - 15000uA |
1200uA - 15000uA |
Leakage Current Peak Display |
Range |
Frequency |
Basic Accuracy |
Range 1-4 |
DC, 1kHz ~ 1MHz |
±(10% of reading + 10uA) |
MD Circuit module |
Measuring Device(MD) |
A, B, C, D, E, F, G |
MD A. UL544 Non Patient, UL484 |
MD B. UL544 Patient Care |
MD C. IEC60601-1, UL2601-1, EN60601-1 |
MD D. UL1563 |
MD E. UL60950, IEC60950, IEC61010-1, IEC60335-1, IEC60990 |
MD F. External MD |
MD G. Basic measuring element 1KΩ of Frequency check |
MD Components |
Resistace accuracy = 1%; Capacitance accuracy = 5% |
MD Voltage Limit |
Maximum 32Vdc |
Internal Leakage |
1. Internal Leakage current = 65uA,
2. 277V applied to Ph max leakage current = 70uA |
Leakage Current Offset |
Range: 0-999.9uA; Resolution: 0.1uA |
DUT Power |
AC Voltage Display |
Range |
30.0 - 300.0V |
Resolution |
0.1V |
Accuracy |
±(1% of reading + 2 counts) |
AC Current |
30A max continuous |
Over current protection |
32A, Response time < 600ms / 68Apeak, Response time < 600ms |
Delay Time |
Range |
0, 1.0 - 999.9s (0=continuous) |
Resolution |
0.1s |
GENERAL |
PLC Remote Control |
Input : Test, Reset, and Recall Memory 1 through 3 |
Output:- Pass, Fail, Processing |
Memory |
99 memories, 8 setps / memory |
Display |
20 x 2 OLED |
Alarm Volume Setting |
Ranger: 0-9; 0=OFF, 1 is softest volumne, 9 is loudest volume |
Key Lock |
To prevent unauthorized alteration of the test Parameters |
Calibration |
Software and adjustments are made through front panel |
Interface |
optional USB & RS232, GPIB |
Environment |
0-40℃, 20-80% RH |
Dimensions(W×H×D), mm |
430×89×400 |
Net Weight |
11.5kg |
*product specifications are subject to change without notice. |